General Facility Information
| Name: | 10 West 66th Street Corp. |
| Address: | 10 West 66th Street |
| City: | New York |
| State: | NY |
| Zip Code: | 10023 |
| County: | New York |
| Category: | Multi-Family Residence |
| Facility Website: | |
| SIC: | 65 - Real Estate |
| NAICS: | 53 - Real Estate and Rental and Leasing |
| ISO Zone: |
J
- New York City
|
| Electric Utility: | Consolidated Edison |
| Gas Utility: | Consolidated Edison Co-NY Inc |
| Time Zone: | Eastern Time |
| Latitude: | 40.722 deg N |
| Longitude: | 73.979 deg W |
| Altitude: | 72 feet MSL |
| Developer Name: | DSM Engineering |
| Developer Website: | |
| NYSERDA Project Number: | 6546 |
| NYSERDA Project Manager: | Joe Borowiec |
| DG System Ownership: | |
| DG System Enclosure: | Indoor |
| System Application: | Combined Heat and Power |
|
| Number of Power Units: | 1 |
| Primary Fuel: | Natural Gas |
| Total Installed Capacity: | 70 kW |
| Operating Hours Per Day: | 24 |
| Operating Days Per Week: | 7 |
| Operating Months Per Year: | 12 |
| Peak Electric Demand: | |
| Total Annual Electricity Usage: | |
| Total Annual Gas Consumption: | |
| Number of Heat Exchangers: | 1 |
| Standalone Capability: | |
| Heat Supply Temperature: | |
| DG System Installation Cost: | |
| Third Party Operation: | No |
| Third Party Maintenance: | No |
| Maintenance Cost: | |
| Government Subsidies: | |
| Chiller Efficiency: | |
| Boiler Efficiency: | |
| Electricity Export to Grid: | No |
| Facility Electric Service Voltage: | |
| Gas Commodity Purchased: | Yes |
| Average Gas Cost: | |
| Average Fuel LHV: | 920 |
|
| Base Electric Rate: |
SC 9-1 General Large - Low Tension; New York City -
Nov05-Oct06
|
| CHP Electric Rate: |
SC 14RA Standby - SC 9-1 Base; Low Tension; New York City -
Nov05-Oct06
|
| CHP Contract Demand: | 350 |
|
NYSERDA Incentive Program Information
|
Unit 1
|
| Description: |
Microturbine |
| Manufacture Date: |
07/01/2004 |
| Installation Date: |
07/01/2004 |
| Commission Date: |
07/01/2004 |
| Decommission Date: |
|
| Installed Capacity: |
70 kW |
| Efficiency: |
28 % |
| Thermal Output: |
0.3 MMBtu/h |
| Technology Group: |
Microturbine
(Recuperated)
|
| Prime Mover: |
Microturbine |
| Fuel: |
Natural Gas |
| Generator Type: |
Inverter |
|
| Prime Mover Manufacturer: |
Ingersoll-Rand |
| Prime Mover Model: |
I-R PowerWorks 70 |
| Heat Recovery: |
Hot Water |
| Primary Heat Recovery Use: |
Domestic Hot Water |
| Secondary Heat Recovery Use: |
Space Heating |
| Emissions Control Technology: |
Combustion Controls |
| Genset Packager: |
|
| System Installer: |
DSM Engineering |
| Component Integration: |
Customer Assembled |
| Controller: |
Third-party Off-the-shelf |
| Demonstration PON: |
554 |
|
Reports and Other Information
|
Facility Details
Facility Documentation
Project Websites
Related Webpages
None
|
Online Monitored Data Reports
Standardized Monitored Data Reports
Operational/Reliability Reports
Emissions Reports
None
|
|